Our Gallery - Waterproofing Repair |
| The first thing you would do is
prepare the substrate by removing any loose crumbly substrate,
make sure the substrate is clean, dry, free of any previous
applied products, and foreign matter. In some cases sandblasting
or environmentally safe paint removers may be required. |
 |
 |
Prime the substrate with 1 coat of PermaFlex
(240 sq ft per gal).
Patch and profile any joints, seams, cracks, holes, etc...
using LRB/TAV mixture. |
 |
 |
| Topcoat using 1 coat of PermaFlex (240 sq ft
per gal). Concrete block walls will need another coat. Once
the products have been applied, not a single molecule of water,
moisture, or vapor can ever enter the basement. Sanitred products
also eliminate problem radon as well. |
 |
 |
| Toilet Waterproofing Repair
in Clear Finish |
Technical Data
Physical
Property Test Method Results
Dry Film Thickness per coat 14 + 2 mils
Hardness ASTM D-2240 Shore A 80 + 5
Shelf Life 24 months
Flash Point- NONE (non-flammable)
Specific Gravity 1.19
Tear Resistance ASTM D-624 Die C 320 pli
Tensile Strength ASTM D-412 2,030 psi
Adhesive Strength ASTM D-903 400 pli
Negative Hydrostatic Vacuum ASTM C-1244 5 min. @ 12 in.(when
combined with 1/6" application of LRB-TAV mixture reinforcement)
Negative Hydrostatic Air Pressure Rev. ASTM C-1244 5 min.
@ 10 lbs.(when combined with 1/6" application of LRB-TAV
mixture reinforcement)
Total Solids by Weight ASTM D-2369 92.2%
Total Solids by Volume ASTM D-2697 89.5%
Ultimate Elongation ASTM D-412- 590%
Abrasion Resistance ASTM D-421-15t 800mg. Taber Abraser
H-18 wheel, 1,000 cycles No Significant Effect
Viscosity at 24°C (75°F) 5000 + 900cpoises
Volatile Organic Compounds ASTM D-2369-81 0.65 Ibs./gallon
|